Product Details
Place of Origin: China
Brand Name: WONSUN
Certification: ISO,CE
Model Number: WSLD
Payment & Shipping Terms
Minimum Order Quantity: 1PC
Price: 1-35 USD
Packaging Details: Packed in bubble wrap firstly, and then reinforced with carton for outer packing.
Delivery Time: 3-7 working days after received your payment
Payment Terms: T/T,Western Union,Money Gram,Alibaba Trade Assurance,Paypal etc.,
Supply Ability: 1000 Sets/Month
Name: |
Single Loop Detector |
Usage: |
Single Channel |
Color: |
Red |
Reaction Time: |
100ms |
Size: |
74x35x85 Mm (L X W X H) |
Name: |
Single Loop Detector |
Usage: |
Single Channel |
Color: |
Red |
Reaction Time: |
100ms |
Size: |
74x35x85 Mm (L X W X H) |
Application Scope |
♦ Parking lot entrances vehicle detection
|
Main Features |
♦ Industrial engineering design concept ♦ When the DIP switch is on position or changing the presence output time, Self-detection would be done ♦ ABS align to the pillar which can combine with each other compactly
|
Work Indicator |
Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power, this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.
|
DIP SWITCH and Wire Jumper |
DIP1, 2 setting the sensitivity;set the presence output time of relay 1 by DIP3;set the relay2 as presence/ pulse output by DIP4; the output time of presence signal set by DIP5;DIP6set the frequency; jumper wire connect to the open end, PIN16 connect to the NO of relay 1. Jumper wire connect to the close end, PIN16 connect to the NC of relay 1. |
Work Frequency |
User can change the loop's work frequency which can avoid the cross talk by the adjacent loop or environment frequency. It offers two styles frequency, set by DIP6 |
Sensitivity Adjustable |
The DIP1,DIP2 on the front panel can adjust the sensitivity. If the vehicle has not any response when test it, the sensitivity should be improved.
|
Technical Data |
Supply voltage AC | 220V, 110V, 24V, 12V |
Supply voltage DC | 24V, 12V |
Sensitivity | Adjustable in 3 Increments (high .medium. low) |
Operating Temperature | -20°C to +65°C |
Storage temperature | -40°C to +85°C |
Frequency Range | 20 kHz to 170 kHz |
Reaction Time | 100ms |
Loop inductance | Ideal: 80μH to 300μH (incl. conn. wiring): max: 50μH to500μH |
Loop connection | <5m optimal |
Loop connection wiring | Maximum length 200 meters Twisted at least 20 times per meter |
Dimensions | 35x74x85 mm (WxHxL) |
Net Weight | 300g |