Product Details
Place of Origin: China
Brand Name: WONSUN
Certification: CE
Model Number: WSTV-410
Payment & Shipping Terms
Minimum Order Quantity: 1PC
Price: nEGOTIATE
Packaging Details: Packed in bubble wrap firstly, and then reinforced with carton for outer packing.
Delivery Time: 3-7 working days after received your payment
Payment Terms: T/T,Western Union,Money Gram,Alibaba Trade Assurance,Paypal etc.,
Supply Ability: 1000 Sets/Month
Supply Voltage: |
220V AC , 115V AC,24VDC/AC,12V DC/AC |
Frequency Range: |
20 KHz To 170 KHz |
Storage Temperature: |
-40°C To +85°C |
Power Consumption: |
4.5VA |
Output Relays: |
240V/5A |
Voltage Tolerance DC: |
±15% |
Supply Voltage: |
220V AC , 115V AC,24VDC/AC,12V DC/AC |
Frequency Range: |
20 KHz To 170 KHz |
Storage Temperature: |
-40°C To +85°C |
Power Consumption: |
4.5VA |
Output Relays: |
240V/5A |
Voltage Tolerance DC: |
±15% |
Double-channel loop detector wholesale for car parking barrier gate system
Quick Detail:
vehicle loop detector
Application
Loop detectors are used wherever vehicles have to be detected. Like monitoring and safe guarding access ways to counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parks.
The WSTV-410 is a single channel inductive loop detectors. The principle is based on a change in the inductance within the loop which is caused by the metallic components of passing vehicles. The changes are picked up and evaluated by a microprocessor. Ease of use thanks to automatic calibration when the operating voltage is applied.
Features:
Single channel inductive loop detectors
Principle is based on change in inductance within loop which is caused by metallic components of passing vehicles
Changes are picked up and evaluated by a microprocessor, easy to use due to automatic calibration when operating voltage is applied
Used wherever vehicles have to be detected, like monitoring and safe guarding access ways for counting vehicles
Output signal can be used for controlling door and gate drive mechanisms, road barriers, controlling traffic light systems in car parks or activating card dispensers in car parks
Specification:
Supply voltage AC | 220V, 110V, 24V, 12V |
Supply voltage DC | 24V, 12V |
Sensitivity | adjustable in 3 increments (high .medium. low) |
Operating temperature | -20°C to +65°C |
Storage temperature | -40°C to +85°C |
Frequency range | 20 kHz to 170 kHz |
Reaction time | 100ms |
Loop inductance | Ideal:80μH to 300μH |
(incl. conn. wiring) | max:50μH to500μH |
Loop connection | <5m optimal |
Loop connection wiring | Maximum length 200 meters |
Twisted at least 20 times per meter | |
Dimensions | 36 x74x85 mm |